Blowing our way to glory
Introduction:
We designed, manufactured and installed the Backward Curved (BC) Industrial fan for a leading cement manufacturer in Telangana in the FY 2020-21.The application for which we catered was for a complete Pulse Jet Bag Filter arrangement to handle the massive dust emissions and following the stringent norms related to the emissions of the particular matter.
Test Conducted:
The Performance Test was conducted and the results are mentioned below:-
Data/ Table:
Given are the different parameters specified in Table 1 with the installation of ID Fan with our Client in Telangana.
Table 1: Design parameters of the ID Fan
Sl. No. | Description | Unit | Value |
1. | Fan Volume | CMH | 7,92,000 |
2. | Pressure | mmwg | -350 |
3. | Gas Temperature | 0C | 240 |
4. | Dust Load | gm/ Nm3 | <=30 |
5. | Efficiency | % | 82.5 |
6. | Fan Speed | RPM | 980 |
7. | Impeller Diameter | mm | Ø 2256 |
8. | Motor Rating | Kw/ Rpm | 1175/ 990 |
9. | ISO/Grade | 1940/ 2.5 | |
10. | Shaft MoC | EN8 – Forged (UT Tested) |
Special Notes:
Clair took up the challenge and following was implemented:
Pictures:
Figure 1: Our fan installation at the site during its erection phase in the state of Telangana.
Figure 2: Our 3D drawing of the fan supplied to this particular cement client in Telangana.