ID Fan Manufacturing milestone

Introduction:

We designed, manufactured and installed the Backward Curved (BC) Industrial fan for a cement manufacturer in Madhya Pradesh in February 2014.The application for which we catered was for a Vent Separator Circulating Fan to be installed in the cement unit.

Test Conducted:

The Performance Test was conducted and the results are mentioned below:-

Data/ Table:

Given are the different parameters specified in Table 1 with the installation of ID Fan with our cement Client in Madhya Pradesh.

Table 1: Design parameters of the ID Fan

Sl. No.

Description

Unit

Value

1.

Fan Volume

CMH

2,00,000

2.

Pressure

mmwg

418

3.

Gas Temperature

0C

100

4.

Dust Load

gm/ Nm3

60

5.

Efficiency

%

73.3

6.

Fan Speed

RPM

980

7.

Impeller Diameter

mm

Ø 2060

8.

Motor Rating

Kw/ Rpm

355/ 990

9.

ISO/Grade

 

1940/ 2.5

10.

Shaft MoC

 

EN8 – Forged (UT Tested)

Special Notes:

Clair took up the challenge and following was implemented:

  • Single Width Single Inlet
  • Simply Supported
  • Erosion Protection : Chromium Carbide Liner on Impeller
  • Bolted type liner for Scroll & fan Casing
  • Mech Design temp is 150OC

Pictures:

Figure 1: Side view of the Assembled Vent Separator Circulating Fan designed at our manufacturing facility.

Figure 2: Front view of the Assembled Vent Separator Circulating Fan designed at our manufacturing facility.