ID Fan Manufacturing milestone
Introduction:
We designed, manufactured and installed the Backward Curved (BC) Industrial fan for a cement manufacturer in Madhya Pradesh in February 2014.The application for which we catered was for a Vent Separator Circulating Fan to be installed in the cement unit.
Test Conducted:
The Performance Test was conducted and the results are mentioned below:-
Data/ Table:
Given are the different parameters specified in Table 1 with the installation of ID Fan with our cement Client in Madhya Pradesh.
Table 1: Design parameters of the ID Fan
Sl. No. | Description | Unit | Value |
1. | Fan Volume | CMH | 2,00,000 |
2. | Pressure | mmwg | 418 |
3. | Gas Temperature | 0C | 100 |
4. | Dust Load | gm/ Nm3 | 60 |
5. | Efficiency | % | 73.3 |
6. | Fan Speed | RPM | 980 |
7. | Impeller Diameter | mm | Ø 2060 |
8. | Motor Rating | Kw/ Rpm | 355/ 990 |
9. | ISO/Grade | 1940/ 2.5 | |
10. | Shaft MoC | EN8 – Forged (UT Tested) |
Special Notes:
Clair took up the challenge and following was implemented:
Pictures:
Figure 1: Side view of the Assembled Vent Separator Circulating Fan designed at our manufacturing facility.
Figure 2: Front view of the Assembled Vent Separator Circulating Fan designed at our manufacturing facility.