Our strength in ID Fans

Introduction:

We designed, manufactured and installed the Backward Curved (BC) Industrial fan for a cement manufacturer in Kenya in April 2014.The application for which we catered was for a Circulating Air (CA) fan to be installed in the cement unit.

Test Conducted:

The Performance Test was conducted and the results are mentioned below:-

Data/ Table:

Given are the different parameters specified in Table 1 with the installation of ID Fan with our Kenyan Client.

Table 1: Design parameters of the ID Fan

Sl. No.

Description

Unit

Value

1.

Fan Volume

CMH

10,20,000

2.

Pressure

mmwg

-400

3.

Gas Temperature

0C

240

4.

Dust Load

gm/ Nm3

15

5.

Efficiency

%

83.5

6.

Fan Speed

RPM

980

7.

Impeller Diameter

mm

Ø 2388

8.

Motor Rating

Kw/ Rpm

1550/ 990

9.

ISO/Grade

 

1940/ 2.5

10.

Shaft MoC

 

EN8 – Forged (UT Tested)

Special Notes:

Clair took up the challenge and following was implemented:

  • Double Width Double Inlet (DWDI)
  • Simply Supported
  • Cone shape blade strengthening ring
  • Fan Engineering drawings Developed in 3D (Auto desk Inventor)
  • Fan Volume 10.2 Lakh CMH

Figure 1: Manufactured Impeller at our facility.

 

Figure 2: The entire arrangement of the facility at Kenya.

Copyright © 2022 Clair Engineers Pvt Ltd.